Hardware specification/Switch Analyzer SA5

Number of contact timing channels: 6
Closed contact current with internal source: 1 mA
External source contact voltage: +15 - +400 VDC
Reaction time, any timing channel: < 20 microsek
Input connectors, any timing channel: Touch-protected jacks
Protection level, any timing channel: 3

Operating coil source inputs (Uc, COM): 1
Source voltage measuring range DC: 0 – 300 V ±1% or ±1 V
Source voltage measuring range AC: 0 – 300 V ±2% or ±2 V
Number of operating coil outputs (OPEN, CLOSE): 2
Coil current measure range DC: 0 – 30 A ±1% or ±0,1 A
Coil current measure range AC: 0 – 30 A ±2% or ±0,2 A
Coil trig reaction time: < 20 micrsek
Internal current limit: 35 A

Protection level 1 (external connections and case)
ESD resistance: IEC 1000-4-2 L4 Radiated electromagn. field res. (27-1000 MHz): IEC 1000-4-3 L3
Burst resistance: IEC 1000-4-4 Pulse resistance: IEC 1000-4-5

Protection level 2 (full isolation)
Protection according to: level 1 Allowed between contact point(s) and earth: =±400 VDC, 285 VAC

Protection level 3 (full isolation, full protection)
Protection according to: level 2 Allowed between any ind. level 3 contact point: = ±400 VDC, 285 VAC

Number transducer inputs: 2
Digital input receiver type: RS422
Analogue input measuring range: 0 – 5 V
Analogue input impedance: 200 kohm 30pF
Analogue transducer minimum resistance: 100 ohm
Power supply, both: 5 V, 100 mA
Input connectors, transducer channels: LEMO Series 2K, 8 p
Protection level any transducer input: 2

Number of aux inputs (Uk, Ul, Um, COM): 3
Input voltage measure range DC: 0 – 300 V ±1% or ±1 V
Input voltage measure range AC: 0 – 300 V ±2% or ±2 V
Input impedance: 1 Mohm 30pF
Number of outputs (MOTOR supplied from Um): 1
Motor current measure range DC: 0 – 50 A ±1% or ±0,1 A
Motor current measure range AC: 0 – 50 A ±2% or ±0,2 A
Input conns, coil and auxiliary inputs/outputs: Touch-protected jacks
Prot level coil and auxiliary inputs/outputs: 3

Serial communication interface type: RS232
Serial communication baud rate: 115 kbps
Serial communication connector type: 9 pole female D-sub
Protection level serial communication : 2

Power supply input AC voltage: 85 – 265 V, 50 – 60 Hz
Power supply input DC voltage: 100 – 375 V
Power requirement: < 50 VA
Main fuse: 2 At
Input connector type: IEC320
Protection level power input pins: 3

Internal sampling rate(adjustable): 10Hz - 50 kHz
Max sampling time example 1: at 100Hz 211Sek
Sampling time example 2: at 50kHz 400ms

Ambient operating temperature range: -20° - +50° C
Ambient storage temperature range: -40° - +70° C
Ambient relative humidity (non-condensing): 0% - 97%

Dimensions: 458x331x153 mm (18"x13"x6")
Weight: 8,6 kg

 

 

 