Our Products

Your need for complete and accurate analysis of your breakers is recognised by Elcon.

As one of the world's leading suppliers of breaker test equipment used by breaker experts worldwide.

Product Info

Training & Education

Elcon Competence Center represents the educational department of Elcon International.

Get the knowledge to use the full capability of our test systems!

Read More

Testing Your Breakers

Your need for complete and accurate analysis of your breakers is recognised by ELCON as one of the world's leading suppliers of breaker test equipment. Founded in 1979 with breaker testing in focus. We deliver smart and professional solutions for your everyday work with high voltage products and switchgear products.

  • Air Damper Test Software 1.0.6.0 2022-07-01

    Only registered and logged in users can download this file!

    Note! Before installing software make sure you have the following microsoft packages installed. If you are installing on a new computer Net framework 4.8 or later is required to be installed before to use this software.

    Download Net Framework Here 

    To install the program you must have administrator rights. To make sure that you are an administrator on the computer, right-click the installation icon for the program, and then click: Run as administrator. If you're prompted for an administrator password or confirmation, type the password or provide confirmation.

    This software works for the following 32 and 64 bit Microsoft operating systems. 

    Microsoft Windows 10
    Microsoft Windows 11

    ADT10 SOFTWARE V 1.0.6.0

    • Added message box indicating database file is missing
    • Upgraded to .Net Framework 4.8
    • Removed unused code
    • Updated components to latest version. 
  • LTUE Configurator V1.1.0.2147 2021-11-22

    Only registered and logged in users can download this file!

    Software for use with LTUE-230 & LTUE-115

    Note! Before installing software make sure you have the following microsoft packages installed.

    Net framework 4.8 or later is required to be installed to use this software.

    Donwload Net Framework 4.8 Here 

    This software works for the following 32 and 64 bit Microsoft operating systems. 

    Microsoft Windows 7 Home Basic SP1 or later
    Microsoft Windows 7 Home Premium SP1 or later
    Microsoft Windows 7 Professional SP1 or later
    Microsoft Windows 7 Enterprise SP1 or later
    Microsoft Windows 7 Ultimate SP1 or later
    Microsoft Windows 8
    Microsoft Windows 8 Pro
    Microsoft Windows 8 Enterprise
    Microsoft Windows 8.1
    Microsoft Windows 8.1 Pro
    Microsoft Windows 8.1 Enterprise
    Microsoft Windows 10
    Microsoft Windows 10 Pro

    Changelog

    Version 1.1.0.2147

    1. Fixed could not open connection using paired Bluetooth stick.
    2. Changed framework to 4.8

    Version 1.1.0.2037
    1. Fixed sometimes calibration guide would freeze.
    2. Revision build number is now year and week

    Version 1.1.0.0
    1. Updated GUI
    2. Added creation of log files.

    Version 1.0.1.3
    1. Fix bug. Communication retransmits did not occur.
    2. Fix Scaling of windows according to windows settings.
    3. Added firmware V1.06 Please read user manual page 20 how to update firmware.
    4. Upgraded Net framework to 4.5.2

    Version 1.0.1.2
    1. Fix password window did not get focus correctly.
    2. Improved firmware upload.
    3. Updated firmware to V1.04. Fix for wrong AC out.
    Please read user manual page 20 how to update firmware.
    4. Various minor fixes.

    Version 1.0.1.1
    1. Rebuild of previous version since executable was not correct in installation.

    Version 1.0.1.0
    1. Fix loss of connection during transfer of curves with Bluetooth in Windows 10.
    2. Updated to Net Framework 4.5
    3. Updated firmware to V1.03 Fix detection of incorrect PF indication.
    Please click read user manual page 20 how to update firmware.
    4. Update manual to Revision 4.

  • Operating Test V 1.9.0.9 for SFG Tester V1

    Only registered and logged in users can download this file!

     

    Operating test software for SFG tester made earlier than 2013.

    To install the program you must have administrator rights.

    To make sure that you are an administrator on the computer, right-click the installation icon for the program, and then click Run as administrator. Administrator permission required! If you're prompted for an administrator password or confirmation, type the password or provide confirmation.

    This software works for the following 32 and 64 bit Microsoft operating systems. 

    Microsoft Windows 7 Home Basic SP1 or later
    Microsoft Windows 7 Home Premium SP1 or later
    Microsoft Windows 7 Professional SP1 or later
    Microsoft Windows 7 Enterprise SP1 or later
    Microsoft Windows 7 Ultimate SP1 or later
    Microsoft Windows 8
    Microsoft Windows 8 Pro
    Microsoft Windows 8 Enterprise
    Microsoft Windows 8.1
    Microsoft Windows 8.1 Pro
    Microsoft Windows 8.1 Enterprise

  • Operating Test V 2.0.0.11 for SFG Tester V2

    Only registered and logged in users can download this file!

     

    Operating test software for SFG tester made 2013 and later.

    To install the program you must have administrator rights.

    To make sure that you are an administrator on the computer, right-click the installation icon for the program, and then click Run as administrator. Administrator permission required. If you're prompted for an administrator password or confirmation, type the password or provide confirmation.

    This software works for the following 32 and 64 bit Microsoft operating systems. 

    Microsoft Windows 7 Home Basic SP1 or later
    Microsoft Windows 7 Home Premium SP1 or later
    Microsoft Windows 7 Professional SP1 or later
    Microsoft Windows 7 Enterprise SP1 or later
    Microsoft Windows 7 Ultimate SP1 or later
    Microsoft Windows 8
    Microsoft Windows 8 Pro
    Microsoft Windows 8 Enterprise
    Microsoft Windows 8.1
    Microsoft Windows 8.1 Pro
    Microsoft Windows 8.1 Enterprise

  • BCM Revision Notes

    Only registered and logged in users can download this file!

    BCM1 Switch monitor

    V3.2001
    - Fixed bug that could make motor operation not to be read by OLM server program.
    V3.20
    - Accuracy for start time of operation recording increased from +-1 second to +-100us. This makes it possible to see the time between two operations with +-100us resolution.BCM1 Switch monitor
    V3.2001
    - Fixed bug that could make motor operation not to be read by OLM server program.
    V3.20
    - Accuracy for start time of operation recording increased from +-1 second to +-100us. This makes it possible to see the time between two operations with +-100us resolution.
    V3.10
    - Added possibility to use the line current inputs for SF6 moisture sensors.
    V3.00
    - Time resolution is improved from 0.5 to 0.1 ms.
    - Pre sample selectable from 10 ms to 80 ms.
    - Fully separate monitoring of the Trip2/Close2 coil.
    - Monitor generated alarms for SF6 and pressure.
    V2.99
    - Added the possibility to read four coil current using three inputs.
    - Added "Automatic Offset Adjustment" for active current transducers.
    - Added settable trig level.
    V2.97
    - Adjustment of motor sampling routine.
    V2.96
    - Changed SF6 sensor reading routine.
    V2.95
    - Added “Oil Pressure Sensor” Max range and type setting.
    Caution! If you are using Oil Pressure Sensor, you must resave the configuration with BCM Installer 1.5.8, after upgrading to this version.
    V2.94
    - Change current trig to trig on both negative and positive signals.
    - Added “Oil Pressure Sensor” 0 – 100MPa.
    Caution! If you are using current trig, you must resave the configuration with BCM Installer 1.5.7, after upgrading to this version.
    V2.91
    - Change routine for detecting bad current sensor.
    V2.90
    - New option: Trig on current is now possible. When upgrading from a previous version you will lose all collected data in the monitor.
    V2.63
    - Some minor bugs fixed.
    V2.59
    - Better precision for the Real-Time-Clock.
    - Remote manual reset of alarm relay is now not possible if "Remote alarm" is not checked.
    V2.58
    - Fixed. Alarm relay activated for every server scan.
    V2.57
    - Trig filtering adjusted.
    - Fixed calculation of spring time (wrong time displayed if time >32s).
    - If you use res1/res2 for trig2 and disable trig1 coil current reading, coil current reading for trig2 now also is disabled.
    - If the motor runs for a longer time than set in the configuration, nothing was saved and a misleading alarm was given (Sensor Fault). This is changed so a motor record is saved after the time set in the configuration has run out and a "Motor Supervision"-alarm is generated.
    V2.56
    - Fixed alarm status inputs.
    V2.55
    - Change coil configuration, coil current for second trip or close coil is read from first coils input when using RES1 or RES2 inputs.
    V2.54
    - Possible to manually set baud rate in monitor to 9600, 19200, 38400 and 115200 Baud.
    - Fixed error that caused settings not to be saved in EPROM when trig signal was received.
    - Fixed motor events < 1 sec is now discarded.
    - Added alarm for coil and line current sensor fault
    - Fixed disable of sensor fault on density and oil pressure sensor.
    V2.53
    - Fixed alarm messages "no coil current", when coil current is disabled.
    V2.52
    - Fixed saving of records when coil current is disabled.
    V2.51
    - Added more settings for coil/motor trigger configuration.
    V2.50
    - Added more settings for coil/motor trigger configuration.
    - Added "Oil Pressure" parameter to event and motor records.
    V2.46
    - Modified coil and motor supervision routines
    V2.45
    - Fixed Too Many Retransmit.
    - Fixed False Trigs.

    BCM Explorer
    V2.4.6
    - Fixed Import/Export function not working.
    - Fixed Upgrade of old database not working.
    - Added "Line fit" calculation method for speed calculation. Previous method called "Line" is now called "2 point"
    V2.4.4
    - Fixed bug that under certain situations could cause Explorer to "crash".
    V2.4.2
    - Added Date/Time fields in database.
    - Added option to clear alarm relay through database field.
    - Added option to automatically turn any upside down motor/coils currents the right way.
    V2.4.0
    - Accuracy for start time of operation recording increased from +-1 second to +-100us. This makes it possible to see the time between two operations with +-100us resolution.
    V2.3.0
    - Added possibility to use the line current inputs for SF6 moisture sensors.
    V2.2.35
    - Fixed that sometmes then using SQL Server data was not imported to the database.
    V2.2.34
    - Change import of typedata. After import the parameter settings are updated to reflect the current configuration.
    V2.2.32
    - Fixed upgrade of database routine.
    V2.2.32
    - Bug fixes.
    V2.2.30
    - Time resolution is improved from 0.5 to 0.1 ms.
    - Pre sample selectable from 10 ms to 80 ms.
    - Fully separate monitoring of the Trip2/Close2 coil.
    - New parameter (Operation time spread).
    - Damping unit monitoring for ABB circuit breakers (length, time, start, travel()).
    - Image contact monitoring for ABB circuit breakers (t1, t2, t3).
    V2.2.27
    - Fixed "Error 91" that could appear during certain conditions.
    - Added "Compact Database" function under "file" menu.
    - Added "CntStatus" to "Power Off" and "Power On" status records.
    - Change “Contact erosion status” to go from 100% to 0% (as it says in the manual) instead of 0% to 100%.
    - Updated the record sort order. If two events did occur on the same second the displayed order may not be correct.
    - Several small enhancements and fixes.
    V2.2.26
    - Bug fixes for “Working Folder” and “Calculation of SF6 values”.
    V2.2.25
    - Fixed a minor problem that could occur during installation of an object.
    V2.2.24
    - New option under the "file" menu, "Set Working Folder".
    V2.2.23
    - Fixed error when Importing/Exporting typedata.
    V2.2.22
    - Added support for zip-files with "Standard Time Format". If used together with Server version 3.1.12 the times/dates saved in the database will always be "Standard Time". Explorer will adjust for the "Daylight Saving Time" before displaying the times/dates on the screen.
    - Bug fixes.
    V2.2.20
    - Bug fixes.
    - Added new parameter “Coil release current”.
    V2.2.18
    - Fixed bug then installing many objects from the same data address. You have to manually delete the file explorer.dat under My DocumentsBCM for this fix to work.
    V2.2.17
    - Bug fixes.
    V2.2.16
    - Support for six BCM:s on the same object(breaker). The BCM:s should be in address order and setup as L1, L1, L2, L2, L3 and L3 in sensor info.
    - The gas constants are removed and replaced by a number representing the SF6 gas share in %. Caution! If you update an existing database and you are not using 100% SF6, you have to setup the SF6 gas share under “Parameters Calculation Settings”, after the upgrade.
    - New database engine/format to support direct connection to Microsoft SQL Server. You can connect to a Microsoft SQL Server database directly by using the new function “New SQL Server Connection”. The SQL settings are stored in a file with the extension SQL. With the function “Open Database” you can now choose to open a Microsoft Access database (extension MDB) or a previously setup SQL connection (extension SQL). (Tested with Microsoft SQL Server 2005). Caution! If you use a third-party program to access the Microsoft Access database directly, you may need to update it because the format is changed.
    - Changes to better support Microsoft Terminal Server (Tested with Microsoft Terminal Server 2003).
    - Added settings for Oil Pressure Sensor.
    V2.2.15
    - Added new setting for “Oil Pressure Sensor”.
    - Change default database location to "My DocumentsBCM".
    - Fixed “Restrike” calculation. The "Restrike" parameter now is "1" if restrike has occurred and "0" if no restrike has occurred.
    V2.2.13
    - Added separate gas constants for phase L1, L2 and L3.
    V2.2.12
    - Bug fix, "System->Server->Adjust Settings" didn't work for HTTP server connection.
    V2.2.11
    - Added HTTP protocol as an option for downloading files from Server.
    V2.2.10
    - Bug fixes.
    V2.2.5
    - Updated graph window.
    - Added mouse scroll-wheel function to lists.
    - New calculation method for density to pressure.
    V2.2.0
    - Added functions to control new BCM Server service V3.1.0
    V2.1.13
    - Fixed “out of stack space” error.
    V2.1.12
    - Fixed “subscript out of range” error for "Object Condition Messages".
    V2.1.11
    - Fixed “overflow” error for calculation of “SF6 last date to refill”.
    V2.1.10
    - Fixed database can now be accessed by more than one user at a time.
    V2.1.9
    - Fixed bug in deletion of relation correction value.
    - Fixed bug subscript out of range in relation correction calculation when relation correction 20 was lower than value.
    - Fixed 3 decimals for condition parameters.
    - Prevented new gauge unit set to have same name as existing.
    - Creating new gauge unit set now uses the set units selected.
    - Added alphabetical sort button for parameter order.
    V2.1.8
    - Fixed external calculation of erosion.
    - Fixed database can now only be accessed by one user at a time.
    - Added new calculation of Coil current, Coil current derivative.
    - Added following parameters to Close, Open, Close-Open Operation. Coil current, Contact close trig, Contact trip trig, Contact trip2/motor trig, Coil current duration, Coil energy, Coil energy to release.
    - Added following parameters to Open Operation. X7.
    - Added following parameters to Motor Operation. Contact close trig, Contact trip trig, Contact trip2/motor trig, Motor run time, Motor energy.
    V2.1.7
    - Change calculation for line current. “Line current at operation” is always shown, but it’s not added to the sum if the value is below 0,5% of full-scale.
    - Added Portuguese language.
    V2.1.6
    - Fixed calculation bug when using linear contact position values.
    V2.1.5
    - Fixed calculation bug when using nominal stroke length.
    - Fixed contact erosion status [%] value was not retrieved from database.
    V2.1.4
    - Fixed some bugs when using single sensor
    V2.1.3
    - Fixed available remote access connections did not show in list in Windows 2000, XP.
    - Fixed sometimes network error could occur when remote access connection had been established.
    V2.1.2
    - Explorer user manual update.
    - Fixed option to calculate coil armature time was missing.
    V2.1.1
    - Fixed damping time didn’t display any decimal.
    - Added option to calculate coil armature time by coil current or coil current derivate.
    V2.1.0
    - Fixed Use spring for motor trig wasn’t checked if enabled.
    - Fixed Database not accepting zero length strings after latest Microsoft Jet patch.
    - Fixed open coil current couldn’t be displayed when BCM1 Switch monitor version older than version 2.47.
    - Fixed problem unable to install object form local or network folder with only read permissions.
    - Fixed error occurring when alarm if Portuguese language was selected.
    - Fixed “Check for upgrade” detected version incorrect.
    - Modified calculation of coil armature time.
    - Modified structure on condition messages.
    - Added system alarm messages.
    - Added OK message function.
    - Added new parameter “Time in use”.
    - Added display of how many RCV parameters that is added and current RCV parameter number.
    - Added function to save data files received from FTP server on local hard drive.
    - And allot of other new functions and bug fixes.
    V2.0.7
    - Fixed bug that could sometimes cause synchronisation of records to be incorrect.
    - Fixed sometimes error occurred displaying graph.
    V2.0.6
    - Added parameter calculation setting. “External device connected to coil inputs”. “Shunt” or “Current transformer” should be selected corresponding to the equipment attached the object.
    - Fixed alarm message log didn’t show dates in local time.
    - New alarms and warnings from server program. Alarm if server isn’t running and if a monitor isn’t responding.
    - Performance improvements of data scanning.
    - Automatic data scanning will not halt now if error occurs.
    - Some minor bug fixes.
    V2.0.5
    - Fixed Oil pressure could sometimes not be enabled.
    - Fixed disabled and sync points now are not included in calculation of mean value and the standard deviation.
    - Parameter settings window will now remember witch tab was last selected.
    - Added check if limits are equal
    V2.0.4
    - Fixed several bugs with trend alarms.
    - Fixed scaling of curves could sometimes go outside screen.
    - Fixed condition message log window could sometimes fail to display all data.
    - Fixed sometimes not all new data was recalculated.
    - Fixed use of separate limits Operation time, Moving time L1, L2, L3 for sync breaker.
    - Speed improvement when opening main and data windows.
    V2.0.3
    - Fixed bug when searching for new objects and not all objects had been installed.
    - Scale of curves now uses the largest scale on the same axis.
    - Fixed after loading server configuration on the Internet FTP didn’t logoff
    - Added displaying of monitor version and serial in monitor settings.
    - Fixed correct exponent is used when calculating coil and motor current.
    V2.0.2
    - Some minor bugs fixed.
    V2.0.1
    - Fixed bug min scale of curves.
    - Fixed bug in import and export of object.
    V2.0.0
    - Added option to change display order of parameters.
    - Added option of automatic checking and downloading of new versions over Internet.
    - Added option to send alarms by mail.
    - Added selection of object to import from other database.
    - New object installation routine.
    - Improvement on synchronization of records.
    - Fixed bug when drawing graphs not all contacts visible when u1 or u2 current was drawn.
    - Fixed contact position close/open was different to the original contact position.
    - And more
    V1.2.2
    - Many small bugs fixed.
    V1.2.1
    - Fixed failure to load older type data file.
    - Stability and speed improvements on FTP transfers.
    - Added more settings for coil trigger configuration.
    V1.2.0
    - Added more settings for coil/motor trigger to sensor configuration.
    - Added "Oil Pressure" parameter to close, open, close-open and motor records.
    - Added "Pre-Arc time" parameter to close and close-open records.
    - Added min scale limit for the time voltage graphs (min 10% of full-scale).
    - Added, "Use analog travel for oil pressure sensor" to sensor configuration.
    - Fixed unit conversion for RCV values.
    V1.1.20
    - Possible to enable parameters that are disabled with Installer.
    V1.1.19
    - Fixed sometimes server program didn’t shutdown when “Run Server at startup” was unchecked.
    V1.1.18
    - Fixed Contact curves in time diagram displaying improperly
    V1.1.17
    - Fixed Disable of coil current not used.
    - Fixed Operation & motor counter always zero.
    - Fixed Curve window, VAL/RCV/AVR buttons now works.
    - Fixed Close/Open/Close-Open diagrams now show "Point (operation)" instead of "Point" for the X-Axis.

    BCM Installer
    V1.7.0
    - Accuracy for start time of operation recording increased from +-1 second to +-100us. This makes it possible to see the time between two operations with +-100us resolution.
    V1.6.0
    - Added possibility to use the line current inputs for SF6 moisture sensors.
    V1.5.20
    - Fixed then when upgrading firmware from 2.xx to 3.00 , sometimes the new parameters was not cleared to default values.
    V1.5.19
    - Fixed "Heater 1" value in status window.
    V1.5.18
    - Fixed wrong record-length for old version of the Switch Monitor program.
    V1.5.17
    - Time resolution is improved from 0.5 to 0.1 ms.
    - Pre sample selectable from 10 ms to 80 ms.
    - Fully separate monitoring of the Trip2/Close2 coil.
    - Monitor generated alarms for SF6 and pressure.
    V1.5.12
    - Added support "Standard Time Format".
    - Added settings for trig level and "Automatic Offset Adjustment".
    V1.5.10
    - Fixed problem with current conversion constants (again).
    V1.5.9
    - Fixed problem with current conversion constants.
    V1.5.8
    - Added settings for Oil Pressure Sensor.
    V1.5.7
    -Added new setting for “Oil Pressure Sensor”.
    -Changed current trig level calculation, for both negative and positive trig.
    V1.5.4
    -Added auto-baud detection.
    -Added ”tcnt” to calibration constants.
    -External constants are now loaded from saved files.
    V1.5.0
    -Added functions to control new BCM Server service V3.1.0
    -Fixed bug in graph display.
    V1.4.4
    - Fixed wrong value of pulses from digital transducer displayed in measurement window.
    V1.4.3
    - Added Portuguese language.
    V1.4.2
    - Fixed wrong axis was displayed when drawing graph.
    V1.4.1
    - Fixed in measurement window. External constant was not removed on ct2 ct3 inputs
    V1.4.0
    - Added check of serial number before saving sensor info.
    - Fixed bug in automatic calculation of contact position.
    V1.3.2
    - Fixed correct exponent is used when calculating coil and motor current.
    - Added display of Duty cycle of density inputs in measurements window.
    V1.3.1
    - Fixed “select click Error 0” message displayed after getting monitor data.
    V1.3.0
    - Fixed coil configuration bug.
    - Fixed wrong axis label shown when drawing graph.
    - Fixed coil configuration bug can't see any motor data and graph of motor current when using coil configuration 9.
    V1.2.2
    - Small bug fixes.
    V1.2.1
    - Added more settings for coil/motor trigger configuration.
    V1.2.0
    - Added more settings for coil trigger configuration.
    - Added "Oil Pressure" parameter to close, open, close-open and motor records.
    V1.1.15
    -Selection of printer now works.
    -Fixed calculation routines of external constants.
    V1.1.14
    -Fixed Alarm time between motor operations was not saved.
    -Fixed B is never saved as zero value in calibration guide.
    V1.1.13
    - Fixed sometimes server program didn’t shutdown when “Run Server at startup” was unchecked.
    - Changed so that it is possible to load alter and save monitor configurations from file without being connected.
    V1.1.12
    - Fixed Failed to recognize COM1 & COM2 port adapter setting in win95.
    - Fixed program crashed on startup in win95.
    - New auto scaling background in main window.
    V1.1.11
    - New communication routine, now uses windows built in routines if a converter with automatic flow control is used.
    - If a adapter without automatic flow control is used, you still only can use COM1 or COM2. And you also need to run "Reserve Communication Port" and check the port used with the non-automatic adapter.

    BCM Server
    V3.3.3
    -Fixed reading of motor operation that could be missed.
    V3.3.2
    -Update to support Switch Monitor Version 3.20.
    V3.2.0
    -Update to support Switch Monitor Version 3.10.
    V3.1.15
    -Update to handle new data with higher time resolution (Switch Monitor Version 3.00).
    V3.1.12
    -Changed clock reference to "Standard Time". Regardless of the setting in Windows, the Server will always use "Standard Time" (No "Daylight Saving Time"). This will avoid any problems that might occur when the time changes from "Standard Time" to "Daylight Savings Time".
    V3.1.11
    -Upgraded to “Microsoft Framework 2.0”. Remote upgrade from 3.1.10 to 3.1.11 or later is not possible.
    -Change routine for upgrading monitor program from 2.63 or earlier to 2.90 or later.
    V3.1.10
    -Lowered CPU usage.
    V3.1.9
    -Fixed “Priority 0” didn’t work.
    V3.1.8
    -Removed unwanted error messages.
    V3.1.7
    -Added "dir"-function for HTTP client connections.
    V3.1.6
    -Removed unnessesary uploads to ftp-server.
    V3.1.3
    -FTP and scanning routines separated from each other.
    V3.1.0
    -Changed Server is now a service that can run in background even if no user is logged on to the computer.
    -Rewritten in VB.NET 1.1 framework.
    -To reduce disk space, data zip files now contain. 100 Status posts, 100 Alarm posts, 5 Event posts, 20 Motor posts
    V3.0.4
    - Fixed "Memory leak" problem.
    V3.0.3
    - Fixed overflow error message
    V3.0.2
    - Fixed duplicate records being saved in zip-files.
    V3.0.1
    - Fixed duplicate status-records being saved in zip-files.
    V3.0.0
    - Continuous scanning for new data. Status record is saved with the set interval.
    - Adjustments to works with Switch Monitor program version 2.45 or higher (including new version 3.00).
    V1.4.4
    - Fixed bug server set baud rate to 9600 when scanning for new monitor that used address between first and last monitors previously scanned.
    V1.4.3
    - Added Portuguese language.
    V1.4.2
    - Fixed bug server stopped saving files after all data was cleared in monitor
    V1.4.1
    - Added selection of communication ports and baud rates to scan for new sensors.
    V1.4.0
    - Improvements of CPU usage.
    - New error structure.
    - Fixed wouldn’t contact FTP2 server if FTP1 server was invalid.
    - Added support for different baud rates on the same bus.
    - And some bug fixes.
    V1.3.1
    - Fixed Failure to successfully write info file when no configuration available.
    V1.3.0
    - More stability improvements on FTP transfers.
    V1.2.1
    - Stability and reliability improvements on FTP transfers.
    V1.2.0
    - Added "Oil Pressure" parameter to event and motor records.
    V1.1.10
    -Fixed Progress bar didn’t work while transferring data from monitor.
    V1.1.9
    -Fixed that sometimes the COM port wouldn’t close. When using a manual converter.
    V1.1.8
    - Fixed Failed to recognize COM1 & COM2 port adapter setting in win95.
    V1.1.7
    - New communication routine now uses windows built in routines if an automatic converter is used.

  • BCM Setup version 3.1.1

    Only registered and logged in users can download this file!

    This setup includes the complete BCM installation package.
    BCM Monitor V3.2001
    BCM Explorer V2.4.6
    BCM Installer V1.7.0
    BCM Server V3.3.3

    This software works for the following 32 and 64 bit Microsoft operating systems.

    Microsoft Windows XP SP3 or later
    Microsoft Windows XP Pro SP3 or later
    Microsoft Windows 7 Home Basic SP1 or later
    Microsoft Windows 7 Home Premium SP1 or later
    Microsoft Windows 7 Professional SP1 or later
    Microsoft Windows 7 Enterprise SP1 or later
    Microsoft Windows 7 Ultimate SP1 or later

    This software should work but is not tested yet with the following 32 and 64 bit Microsoft operating systems.

    Microsoft Windows 8
    Microsoft Windows 8 Pro
    Microsoft Windows 8 Enterprise
    Microsoft Windows 8.1
    Microsoft Windows 8.1 Pro
    Microsoft Windows 8.1 Enterprise

  • BTS11 V1.6.0.2525 2025-06-25

    Only registered and logged in users can download this file!

    Circuit Breaker Test Software BTS11 (English Only)

    Used for SA10, SA10A, SA5, SA5A, DCM2, BTS2000, BTS2000A.

    To install the program you must have administrator rights.

    To make sure that you are an administrator on the computer, right-click the installation icon for the program, 
    and then click Run as administrator. If you're prompted for an administrator password or confirmation, type the password or provide confirmation.

    Note that "Use separate settings for all users" option will install database and settings files into 'My DocumentsBTS11' folder. Make sure that your 'My Documents Folder' is not stored on a network drive when using this option.

    Microsoft Word is required for protocol printout.
    Microsoft Excel is required for export to Excel.

    Note! Microsoft Office Apps for Windows WILL NOT WORK!

    This software has been tested to work on the following

    Operating system

    • Microsoft Windows 10 32-bits and 64-bits

    • Microsoft Windows 11 32-bits and 64-bits

    Microsoft Office desktop applications for PC

    • Microsoft Office Version 2308 Build 16.0.16731.20310 32-bits and 64-bit
    • Microsoft Office Version 2205 Build 16.0.15225.20348 32-bits and 64-bits

    • Microsoft Office Version 2016 Build 16.0.4266.1001 32-bits and 64-bits

    Version history

    Version 1.6.0.2525
    1. Fixed a minor bug that could make result not appear on some coil current.
    2. Fixed serial input in new test object could cause error on some serial numbers.
    3. Fixed error could occur if nothing was selected in order explorer.
    Version 1.6.0.2450
    1. Fixed unable to create new order.
    2. Fixed coil calculation on extremely fast coils <5ms
    3. Added support for APM SP300 Series Power Supplies that are nearly identical to the APS CPS100 Series.
      Use APS/APM in power supply settings to use these.
      Note that Power supplies needs to be configured to use
      Remote Control: RS232, Baud Rate:115200, Parity Type: NONE, Stop Bits: 1
    Version 1.6.0.2448
    1. Fixed error when Export to email. Database was locked to program even if it was closed when attempting to delete.
    Version 1.6.0.2447
    1. Added IEC standard 62271-108 for disconnecting circuit breakers.
    2. Fixed bug unable to create 1 or 2 pole test objects.
    3. Fixes in Export/Import database
      Switch type did not Export/Import all applications of switch.
      Selecting no to all could overwrite existing data.
      Fixed do not import/export curves with same operation number as existing.
      Improved speed.
    1. Fixed bug that some result values was not locked in test results.
    2. Fixed bug curve would show that was not set to display in DCM operation settings.
    3. Improved performance loading from database
    4. Fixed max scale on travel curves in graph was incorrect when displaying in meters.
    5. Fixed error that could occur when selecting test object in tree.
    6. Added check if function values exit in setup switch type. If no function values exit a question dialog will appear to create.
    Version 1.6.0.2433
    1. Fixed some configurations could prevent printout of travel parameters.
    2. Added information about Workgroup file in database settings.
    3. Fixed graph window would not remember last position.
    Version 1.6.0.2423
    1. Fixed Switch Configuration type of breaker could be empty when saving.
    Version 1.6.0.2422
    1. Fixed input settings was not always read from switch configuration on new test.
    2. Fixed contacts could get missing on merge.
    Version 1.6.0.2421
    1. Fixed Switch configuration.
      Unable to set input connections, could not add function values to old switch type that had no function values.
      Added Set default function values button.
    1. Fixed reference curve not working. Fixed curve drawing of reference curves could fail.
    2. Major improvements of the statistics function. Fixed a memory leak in Statistics.
      Added display of Operation Graph when clicking a Parameter datapoint in Statistics Graph
      Note that when running statistic first time. Operation results will be recalculated to add missing results.
      This might take some time depending on the size of data.
    1. Added function display all results in graph analyze.
    2. Added detection of Peaks in coil current. Use function display all results in graph to show.
    3. Moved FSU Current and Motor current to coil current axis.
    4. Fixed bug in print test protocol. Message No template available when Swedish template was set in old version of software.
    5. Fixed errors when running BTS11 Demo
    6. Adjusted detection level for contact calculation on troublesome DCM curves.
    7. Added calculation of Travel angle and length parameters independent of curve that is displayed.
    8. Improved loading speed of database objects to the main window.
    9. Updated Athen USB comport drivers to latest version.
    10. Other various minor bug fixes and improvements.
    Version 1.6.0.2400
    1. BTS11 and its Setup is now digitally signed by Elcon AB
    2. Fixed wrong filter names was displayed for contacts.
    3. Fixed Overtravel did not calculate on some curves with very low overtravel.
    4. Fixed Rebound calculation did not calculate if rebound was before overtravel.
    5. Fixed bugs in Operation cycle.
    6. Fixed minor bugs in DCM graphs display.
    7. Fixed bug that could occur in DCM Trip contact generation.
    8. Fixed Functions values was missing when import/export switch configuration.
    9. Fixed bugs in Setup Switch Type.
    10. Fixed ratings would not get unpacked properly.
    11. Fixed Main, Graph and Test object window now remember their position when using Snap in Windows 10 and 11.
      Select and drag the window like to Snap to the side or edge of your screen.
    12. Fixed Over travel and Rebound measurement did not work on breakers with overtravel before trip operation.
    13. Fixed error in GetCoilArmatureTime when current was negative.
    14. Other various minor improvements.
  • Linear Table Creator V1.0.0.0

    Only registered and logged in users can download this file!

     

    Application to create linear conversion table for OLM, BCM and BTS11.

    This application is standalon without installer. Just uncompress the Zip file to the location you want.

    This software works for the following 32 and 64 bit Microsoft operating systems. 

    Application to create linear conversion table for OLM, BCM and BTS11.

    This application is standalon without installer. Just uncompress the Zip file to the location you want.

    This software works for the following 32 and 64 bit Microsoft operating systems. 

    Microsoft Windows XP SP3 or later
    Microsoft Windows XP Pro SP3 or later
    Microsoft Windows 7 Home Basic SP1 or later
    Microsoft Windows 7 Home Premium SP1 or later
    Microsoft Windows 7 Professional SP1 or later
    Microsoft Windows 7 Enterprise SP1 or later
    Microsoft Windows 7 Ultimate SP1 or later
    Microsoft Windows 8
    Microsoft Windows 8 Pro
    Microsoft Windows 8 Enterprise
    Microsoft Windows 8.1
    Microsoft Windows 8.1 Pro
    Microsoft Windows 8.1 Enterprise

     
  • LTIB Configurator 1.0.2

    Software for use with IGBT Test Unit LTIB 800/1300

    New LTIB firmware V1.08

    This software has been tested for the following 32 and 64 bit Microsoft operating systems. 

    Microsoft Windows XP SP3 or later
    Microsoft Windows XP Pro SP3 or later
    Microsoft Windows 7 Home Basic SP1 or later
    Microsoft Windows 7 Home Premium SP1 or later
    Microsoft Windows 7 Professional SP1 or later
    Microsoft Windows 7 Enterprise SP1 or later
    Microsoft Windows 7 Ultimate SP1 or later
    Microsoft Windows 8
    Microsoft Windows 8 Pro
    Microsoft Windows 8 Enterprise
    Microsoft Windows 8.1
    Microsoft Windows 8.1 Pro
    Microsoft Windows 8.1 Enterprise

     

    Only registered and logged in users can download this file!

  • LTTE Thyristor Tester V1.1.1.2336 2023-09-08

    Note! Before installing software make sure you have the following microsoft packages installed.

    If you are installing on a new computer Net framework 4.8 or later is required to be installed before to use this software.

    Download Net Framework Here 

    To install the program you must have administrator rights.

    To make sure that you are an administrator on the computer, right-click the installation icon for the program, 
    and then click  Run as administrator. If you're prompted for an administrator password or confirmation, type the password or provide confirmation.

    The software is fully compatible with the following 32 and 64 bit Microsoft operating systems. 

    Microsoft Windows 7 Home Basic SP1 or later
    Microsoft Windows 7 Home Premium SP1 or later
    Microsoft Windows 7 Professional SP1 or later
    Microsoft Windows 7 Enterprise SP1 or later
    Microsoft Windows 7 Ultimate SP1 or later
    Microsoft Windows 8
    Microsoft Windows 8 Pro
    Microsoft Windows 8 Enterprise
    Microsoft Windows 8.1
    Microsoft Windows 8.1 Pro
    Microsoft Windows 8.1 Enterprise
    Microsoft Windows 10
    Microsoft Windows 10 Pro
    Microsoft Windows 11
    Microsoft Windows 11 Pro

    Version History

    Version 1.1.1.2336 2023-09-08
    · Fixed limits on derivative results did not work.
    · New firmware. V1.11 Updated firing test.
    Version 1.1.1.2106 2021-02-11
    · Upgraded .Net framework to V4.8.
    · Fixed Windows on screen keyboard would not show on Windows 10 Version 20H2.
    · New firmware. V1.10

    Version 1.1.1.1922 2019-04-30
    · Upgraded graph to Ver9.
    · Fixed error enabling AutoStart.
    · Upgraded .Net framework to V4.6.
    · Optimized memory handling
    · New firmware. V1.08 Increased timeout for charge relay. Please upgrade to this version.
    · Fixed error when canceling remote control in remote control routine TCP_Server_Listner.
    · Improved handling in TCP_Server_Listner routine.

    Version 1.1.0.0 2017-06-22
    · Added new menu ‘Program Settings’
    · Moved ‘Automatically Start At Windows Login’ and ‘Remote Port’ From ‘LTTE Service’ to new menu ‘Program Settings’.
    · Added option ‘Transfer Test Graph Automatically’ to new menu ‘Program Settings’
    · Added option ‘Save Test Results Automatically’ to new menu ‘Program Settings’
    · Added icon for no curve data available in test results.
    · Updated LTTE User manual to Rev4 2016-06-22.


    Only registered and logged in users can download this file!

  • LTUD Configurator 2.1.0.12

    Only registered and logged in users can download this file!

    Software for use with LTUD 022_011Software for use with LTUD 022_011

    This software works for the following 32 and 64 bit Microsoft operating systems. 

    Microsoft Windows XP SP3 or later
    Microsoft Windows XP Pro SP3 or later
    Microsoft Windows 7 Home Basic SP1 or later
    Microsoft Windows 7 Home Premium SP1 or later
    Microsoft Windows 7 Professional SP1 or later
    Microsoft Windows 7 Enterprise SP1 or later
    Microsoft Windows 7 Ultimate SP1 or later

    This software should work but is not tested yet with the following 32 and 64 bit Microsoft operating systems. 

    Microsoft Windows 8
    Microsoft Windows 8 Pro
    Microsoft Windows 8 Enterprise
    Microsoft Windows 8.1
    Microsoft Windows 8.1 Pro
    Microsoft Windows 8.1 Enterprise

  • OLM Revision notes

    Only registered and logged in users can download this file!

     

    OLM REVISION NOTES 28 October 2011

    OLM2 Switch monitor
    V3.2001
    - Fixed bug that could make motor operation not to be read by OLM server program.
    V3.20
    - Accuracy for start time of operation recording increased from +-1 second to +-100us. This makes it possible to see the time between two operations with +-100us resolution.
    V3.10
    - Added possibility to use the line current inputs for SF6 moisture sensors.
    V3.00
    - Time resolution is improved from 0.5 to 0.1 ms.
    - Pre sample selectable from 10 ms to 80 ms.
    - Fully separate monitoring of the Trip2/Close2 coil.
    - Monitor generated alarms for SF6 and pressure.
    V2.99
    - Added the possibility to read four coil current using three inputs.
    - Added "Automatic Offset Adjustment" for active current transducers.
    - Added settable trig level.
    V2.97
    - Adjustment of motor sampling routine.
    V2.96
    - Changed SF6 sensor reading routine.
    V2.95
    - Added “Oil Pressure Sensor” Max range and type setting.
    Caution! If you are using Oil Pressure Sensor, you must resave the configuration with OLM Installer 1.5.8, after upgrading to this version.
    V2.94
    - Change current trig to trig on both negative and positive signals.
    - Added “Oil Pressure Sensor” 0 – 100MPa.
    Caution! If you are using current trig, you must resave the configuration with OLM Installer 1.5.7, after upgrading to this version.
    V2.91
    - Change routine for detecting bad current sensor.
    V2.90
    - New option: Trig on current is now possible. When upgrading from a previous version you will lose all collected data in the monitor.
    V2.63
    - Some minor bugs fixed.
    V2.59
    - Better precision for the Real-Time-Clock.
    - Remote manual reset of alarm relay is now not possible if "Remote alarm" is not checked.
    V2.58
    - Fixed. Alarm relay activated for every server scan.
    V2.57
    - Trig filtering adjusted.
    - Fixed calculation of spring time (wrong time displayed if time >32s).
    - If you use res1/res2 for trig2 and disable trig1 coil current reading, coil current reading for trig2 now also is disabled.
    - If the motor runs for a longer time than set in the configuration, nothing was saved and a misleading alarm was given (Sensor Fault). This is changed so a motor record is saved after the time set in the configuration has run out and a "Motor Supervision"-alarm is generated.
    V2.56
    - Fixed alarm status inputs.
    V2.55
    - Change coil configuration, coil current for second trip or close coil is read from first coils input when using RES1 or RES2 inputs.
    V2.54
    - Possible to manually set baud rate in monitor to 9600, 19200, 38400 and 115200 Baud.
    - Fixed error that caused settings not to be saved in EPROM when trig signal was received.
    - Fixed motor events < 1 sec is now discarded.
    - Added alarm for coil and line current sensor fault
    - Fixed disable of sensor fault on density and oil pressure sensor.
    V2.53
    - Fixed alarm messages "no coil current", when coil current is disabled.
    V2.52
    - Fixed saving of records when coil current is disabled.
    V2.51
    - Added more settings for coil/motor trigger configuration.
    V2.50
    - Added more settings for coil/motor trigger configuration.
    - Added "Oil Pressure" parameter to event and motor records.
    V2.46
    - Modified coil and motor supervision routines
    V2.45
    - Fixed Too Many Retransmit.
    - Fixed False Trigs.OLM Explorer
    V2.4.6
    - Fixed Import/Export function not working.
    - Fixed Upgrade of old database not working.
    - Added "Line fit" calculation method for speed calculation. Previous method called "Line" is now called "2 point"
    V2.4.4
    - Fixed bug that under certain situations could cause Explorer to "crash".
    V2.4.2
    - Added Date/Time fields in database.
    - Added option to clear alarm relay through database field.
    - Added option to automatically turn any upside down motor/coils currents the right way.
    V2.4.0
    - Accuracy for start time of operation recording increased from +-1 second to +-100us. This makes it possible to see the time between two operations with +-100us resolution.
    V2.3.0
    - Added possibility to use the line current inputs for SF6 moisture sensors.
    V2.2.35
    - Fixed that sometmes then using SQL Server data was not imported to the database.
    V2.2.34
    - Change import of typedata. After import the parameter settings are updated to reflect the current configuration.
    V2.2.32
    - Bug fixes.
    V2.2.30
    - Time resolution is improved from 0.5 to 0.1 ms.
    - Pre sample selectable from 10 ms to 80 ms.
    - Fully separate monitoring of the Trip2/Close2 coil.
    - New parameter (Operation time spread).
    - Damping unit monitoring for ABB circuit breakers (length, time, start, travel()).
    - Image contact monitoring for ABB circuit breakers (t1, t2, t3).
    V2.2.27
    - Fixed "Error 91" that could appear during certain conditions.
    - Added "Compact Database" function under "file" menu.
    - Added "CntStatus" to "Power Off" and "Power On" status records.
    - Change “Contact erosion status” to go from 100% to 0% (as it says in the manual) instead of 0% to 100%.
    - Updated the record sort order. If two events did occur on the same second the displayed order may not be correct.
    - Several small enhancements and fixes.
    V2.2.26
    - Bug fixes for “Working Folder” and “Calculation of SF6 values”.
    V2.2.25
    - Fixed a minor problem that could occur during installation of an object.
    V2.2.24
    - New option under the "file" menu, "Set Working Folder".
    V2.2.23
    - Fixed error when Importing/Exporting typedata.
    V2.2.22
    - Added support for zip-files with "Standard Time Format". If used together with Server version 3.1.12 the times/dates saved in the database will always be "Standard Time". Explorer will adjust for the "Daylight Saving Time" before displaying the times/dates on the screen.
    - Bug fixes.
    V2.2.20
    - Bug fixes.
    - Added new parameter “Coil release current”.
    V2.2.18
    - Fixed bug then installing many objects from the same data address. You have to manually delete the file explorer.dat under My DocumentsOLM for this fix to work.
    V2.2.17
    - Bug fixes.
    V2.2.16
    - Support for six OLM:s on the same object(breaker). The OLM:s should be in address order and setup as L1, L1, L2, L2, L3 and L3 in sensor info.
    - The gas constants are removed and replaced by a number representing the SF6 gas share in %. Caution! If you update an existing database and you are not using 100% SF6, you have to setup the SF6 gas share under “Parameters Calculation Settings”, after the upgrade.
    - New database engine/format to support direct connection to Microsoft SQL Server. You can connect to a Microsoft SQL Server database directly by using the new function “New SQL Server Connection”. The SQL settings are stored in a file with the extension SQL. With the function “Open Database” you can now choose to open a Microsoft Access database (extension MDB) or a previously setup SQL connection (extension SQL). (Tested with Microsoft SQL Server 2005). Caution! If you use a third-party program to access the Microsoft Access database directly, you may need to update it because the format is changed.
    - Changes to better support Microsoft Terminal Server (Tested with Microsoft Terminal Server 2003).
    - Added settings for Oil Pressure Sensor.
    V2.2.15
    - Added new setting for “Oil Pressure Sensor”.
    - Change default database location to "My DocumentsOLM".
    - Fixed “Restrike” calculation. The "Restrike" parameter now is "1" if restrike has occurred and "0" if no restrike has occurred.
    V2.2.13
    - Added separate gas constants for phase L1, L2 and L3.
    V2.2.12
    - Bug fix, "System->Server->Adjust Settings" didn't work for HTTP server connection.
    V2.2.11
    - Added HTTP protocol as an option for downloading files from Server.
    V2.2.10
    - Bug fixes.
    V2.2.5
    - Updated graph window.
    - Added mouse scroll-wheel function to lists.
    - New calculation method for density to pressure.
    V2.2.0
    - Added functions to control new OLM Server service V3.1.0
    V2.1.13
    - Fixed “out of stack space” error.
    V2.1.12
    - Fixed “subscript out of range” error for "Object Condition Messages".
    V2.1.11
    - Fixed “overflow” error for calculation of “SF6 last date to refill”.
    V2.1.10
    - Fixed database can now be accessed by more than one user at a time.
    V2.1.9
    - Fixed bug in deletion of relation correction value.
    - Fixed bug subscript out of range in relation correction calculation when relation correction 20 was lower than value.
    - Fixed 3 decimals for condition parameters.
    - Prevented new gauge unit set to have same name as existing.
    - Creating new gauge unit set now uses the set units selected.
    - Added alphabetical sort button for parameter order.
    V2.1.8
    - Fixed external calculation of erosion.
    - Fixed database can now only be accessed by one user at a time.
    - Added new calculation of Coil current, Coil current derivative.
    - Added following parameters to Close, Open, Close-Open Operation. Coil current, Contact close trig, Contact trip trig, Contact trip2/motor trig, Coil current duration, Coil energy, Coil energy to release.
    - Added following parameters to Open Operation. X7.
    - Added following parameters to Motor Operation. Contact close trig, Contact trip trig, Contact trip2/motor trig, Motor run time, Motor energy.
    V2.1.7
    - Change calculation for line current. “Line current at operation” is always shown, but it’s not added to the sum if the value is below 0,5% of full-scale.
    - Added Portuguese language.
    V2.1.6
    - Fixed calculation bug when using linear contact position values.
    V2.1.5
    - Fixed calculation bug when using nominal stroke length.
    - Fixed contact erosion status [%] value was not retrieved from database.
    V2.1.4
    - Fixed some bugs when using single sensor
    V2.1.3
    - Fixed available remote access connections did not show in list in Windows 2000, XP.
    - Fixed sometimes network error could occur when remote access connection had been established.
    V2.1.2
    - Explorer user manual update.
    - Fixed option to calculate coil armature time was missing.
    V2.1.1
    - Fixed damping time didn’t display any decimal.
    - Added option to calculate coil armature time by coil current or coil current derivate.
    V2.1.0
    - Fixed Use spring for motor trig wasn’t checked if enabled.
    - Fixed Database not accepting zero length strings after latest Microsoft Jet patch.
    - Fixed open coil current couldn’t be displayed when OLM2 Switch monitor version older than version 2.47.
    - Fixed problem unable to install object form local or network folder with only read permissions.
    - Fixed error occurring when alarm if Portuguese language was selected.
    - Fixed “Check for upgrade” detected version incorrect.
    - Modified calculation of coil armature time.
    - Modified structure on condition messages.
    - Added system alarm messages.
    - Added OK message function.
    - Added new parameter “Time in use”.
    - Added display of how many RCV parameters that is added and current RCV parameter number.
    - Added function to save data files received from FTP server on local hard drive.
    - And allot of other new functions and bug fixes.
    V2.0.7
    - Fixed bug that could sometimes cause synchronisation of records to be incorrect.
    - Fixed sometimes error occurred displaying graph.
    V2.0.6
    - Added parameter calculation setting. “External device connected to coil inputs”. “Shunt” or “Current transformer” should be selected corresponding to the equipment attached the object.
    - Fixed alarm message log didn’t show dates in local time.
    - New alarms and warnings from server program. Alarm if server isn’t running and if a monitor isn’t responding.
    - Performance improvements of data scanning.
    - Automatic data scanning will not halt now if error occurs.
    - Some minor bug fixes.
    V2.0.5
    - Fixed Oil pressure could sometimes not be enabled.
    - Fixed disabled and sync points now are not included in calculation of mean value and the standard deviation.
    - Parameter settings window will now remember witch tab was last selected.
    - Added check if limits are equal
    V2.0.4
    - Fixed several bugs with trend alarms.
    - Fixed scaling of curves could sometimes go outside screen.
    - Fixed condition message log window could sometimes fail to display all data.
    - Fixed sometimes not all new data was recalculated.
    - Fixed use of separate limits Operation time, Moving time L1, L2, L3 for sync breaker.
    - Speed improvement when opening main and data windows.
    V2.0.3
    - Fixed bug when searching for new objects and not all objects had been installed.
    - Scale of curves now uses the largest scale on the same axis.
    - Fixed after loading server configuration on the Internet FTP didn’t logoff
    - Added displaying of monitor version and serial in monitor settings.
    - Fixed correct exponent is used when calculating coil and motor current.
    V2.0.2
    - Some minor bugs fixed.
    V2.0.1
    - Fixed bug min scale of curves.
    - Fixed bug in import and export of object.
    V2.0.0
    - Added option to change display order of parameters.
    - Added option of automatic checking and downloading of new versions over Internet.
    - Added option to send alarms by mail.
    - Added selection of object to import from other database.
    - New object installation routine.
    - Improvement on synchronization of records.
    - Fixed bug when drawing graphs not all contacts visible when u1 or u2 current was drawn.
    - Fixed contact position close/open was different to the original contact position.
    - And more
    V1.2.2
    - Many small bugs fixed.
    V1.2.1
    - Fixed failure to load older type data file.
    - Stability and speed improvements on FTP transfers.
    - Added more settings for coil trigger configuration.
    V1.2.0
    - Added more settings for coil/motor trigger to sensor configuration.
    - Added "Oil Pressure" parameter to close, open, close-open and motor records.
    - Added "Pre-Arc time" parameter to close and close-open records.
    - Added min scale limit for the time voltage graphs (min 10% of full-scale).
    - Added, "Use analog travel for oil pressure sensor" to sensor configuration.
    - Fixed unit conversion for RCV values.
    V1.1.20
    - Possible to enable parameters that are disabled with Installer.
    V1.1.19
    - Fixed sometimes server program didn’t shutdown when “Run Server at startup” was unchecked.
    V1.1.18
    - Fixed Contact curves in time diagram displaying improperly
    V1.1.17
    - Fixed Disable of coil current not used.
    - Fixed Operation & motor counter always zero.
    - Fixed Curve window, VAL/RCV/AVR buttons now works.
    - Fixed Close/Open/Close-Open diagrams now show "Point (operation)" instead of "Point" for the X-Axis.OLM Installer
    V1.7.0
    - Accuracy for start time of operation recording increased from +-1 second to +-100us. This makes it possible to see the time between two operations with +-100us resolution.
    V1.6.0
    - Added possibility to use the line current inputs for SF6 moisture sensors.
    V1.5.20
    - Fixed then when upgrading firmware from 2.xx to 3.00 , sometimes the new parameters was not cleared to default values.
    V1.5.19
    - Fixed "Heater 1" value in status window.
    V1.5.18
    - Fixed wrong record-length for old version of the Switch Monitor program.
    V1.5.17
    - Time resolution is improved from 0.5 to 0.1 ms.
    - Pre sample selectable from 10 ms to 80 ms.
    - Fully separate monitoring of the Trip2/Close2 coil.
    - Monitor generated alarms for SF6 and pressure.
    V1.5.12
    - Added support "Standard Time Format".
    - Added settings for trig level and "Automatic Offset Adjustment".
    V1.5.10
    - Fixed problem with current conversion constants (again).
    V1.5.9
    - Fixed problem with current conversion constants.
    V1.5.8
    - Added settings for Oil Pressure Sensor.
    V1.5.7
    -Added new setting for “Oil Pressure Sensor”.
    -Changed current trig level calculation, for both negative and positive trig.
    V1.5.4
    -Added auto-baud detection.
    -Added ”tcnt” to calibration constants.
    -External constants are now loaded from saved files.
    V1.5.0
    -Added functions to control new OLM Server service V3.1.0
    -Fixed bug in graph display.
    V1.4.4
    - Fixed wrong value of pulses from digital transducer displayed in measurement window.
    V1.4.3
    - Added Portuguese language.
    V1.4.2
    - Fixed wrong axis was displayed when drawing graph.
    V1.4.1
    - Fixed in measurement window. External constant was not removed on ct2 ct3 inputs
    V1.4.0
    - Added check of serial number before saving sensor info.
    - Fixed bug in automatic calculation of contact position.
    V1.3.2
    - Fixed correct exponent is used when calculating coil and motor current.
    - Added display of Duty cycle of density inputs in measurements window.
    V1.3.1
    - Fixed “select click Error 0” message displayed after getting monitor data.
    V1.3.0
    - Fixed coil configuration bug.
    - Fixed wrong axis label shown when drawing graph.
    - Fixed coil configuration bug can't see any motor data and graph of motor current when using coil configuration 9.
    V1.2.2
    - Small bug fixes.
    V1.2.1
    - Added more settings for coil/motor trigger configuration.
    V1.2.0
    - Added more settings for coil trigger configuration.
    - Added "Oil Pressure" parameter to close, open, close-open and motor records.
    V1.1.15
    -Selection of printer now works.
    -Fixed calculation routines of external constants.
    V1.1.14
    -Fixed Alarm time between motor operations was not saved.
    -Fixed B is never saved as zero value in calibration guide.
    V1.1.13
    - Fixed sometimes server program didn’t shutdown when “Run Server at startup” was unchecked.
    - Changed so that it is possible to load alter and save monitor configurations from file without being connected.
    V1.1.12
    - Fixed Failed to recognize COM1 & COM2 port adapter setting in win95.
    - Fixed program crashed on startup in win95.
    - New auto scaling background in main window.
    V1.1.11
    - New communication routine, now uses windows built in routines if a converter with automatic flow control is used.
    - If a adapter without automatic flow control is used, you still only can use COM1 or COM2. And you also need to run "Reserve Communication Port" and check the port used with the non-automatic adapter.OLM Server
    V3.3.3
    -Fixed reading of motor operation that could be missed.
    V3.3.2
    -Update to support Switch Monitor Version 3.20.
    V3.2.0
    -Update to support Switch Monitor Version 3.10.
    V3.1.15
    -Update to handle new data with higher time resolution (OLM2 Switch Monitor Version 3.00).
    V3.1.12
    -Changed clock reference to "Standard Time". Regardless of the setting in Windows, the Server will always use "Standard Time" (No "Daylight Saving Time"). This will avoid any problems that might occur when the time changes from "Standard Time" to "Daylight Savings Time".
    V3.1.11
    -Upgraded to “Microsoft Framework 2.0”. Remote upgrade from 3.1.10 to 3.1.11 or later is not possible.
    -Change routine for upgrading monitor program from 2.63 or earlier to 2.90 or later.
    V3.1.10
    -Lowered CPU usage.
    V3.1.9
    -Fixed “Priority 0” didn’t work.
    V3.1.8
    -Removed unwanted error messages.
    V3.1.7
    -Added "dir"-function for HTTP client connections.
    V3.1.6
    -Removed unnessesary uploads to ftp-server.
    V3.1.3
    -FTP and scanning routines separated from each other.
    V3.1.0
    -Changed Server is now a service that can run in background even if no user is logged on to the computer.
    -Rewritten in VB.NET 1.1 framework.
    -To reduce disk space, data zip files now contain. 100 Status posts, 100 Alarm posts, 5 Event posts, 20 Motor posts
    V3.0.4
    - Fixed "Memory leak" problem.
    V3.0.3
    - Fixed overflow error message
    V3.0.2
    - Fixed duplicate records being saved in zip-files.
    V3.0.1
    - Fixed duplicate status-records being saved in zip-files.
    V3.0.0
    - Continuous scanning for new data. Status record is saved with the set interval.
    - Adjustments to works with Switch Monitor program version 2.45 or higher (including new version 3.00).
    V1.4.4
    - Fixed bug server set baud rate to 9600 when scanning for new monitor that used address between first and last monitors previously scanned.
    V1.4.3
    - Added Portuguese language.
    V1.4.2
    - Fixed bug server stopped saving files after all data was cleared in monitor
    V1.4.1
    - Added selection of communication ports and baud rates to scan for new sensors.
    V1.4.0
    - Improvements of CPU usage.
    - New error structure.
    - Fixed wouldn’t contact FTP2 server if FTP1 server was invalid.
    - Added support for different baud rates on the same bus.
    - And some bug fixes.
    V1.3.1
    - Fixed Failure to successfully write info file when no configuration available.
    V1.3.0
    - More stability improvements on FTP transfers.
    V1.2.1
    - Stability and reliability improvements on FTP transfers.
    V1.2.0
    - Added "Oil Pressure" parameter to event and motor records.
    V1.1.10
    -Fixed Progress bar didn’t work while transferring data from monitor.
    V1.1.9
    -Fixed that sometimes the COM port wouldn’t close. When using a manual converter.
    V1.1.8
    - Fixed Failed to recognize COM1 & COM2 port adapter setting in win95.
    V1.1.7
    - New communication routine now uses windows built in routines if an automatic converter is used.
  • OLM Setup version 3.1.1

    Only registered and logged in users can download this file!

     

    This setup includes the complete OLM installation package.

    OLM Monitor V3.2001
    OLM Explorer V2.4.6
    OLM Installer V1.7.0
    OLM Server V3.3.3

    This software works for the following 32 and 64 bit Microsoft operating systems. 

    Microsoft Windows XP SP3 or later
    Microsoft Windows XP Pro SP3 or later
    Microsoft Windows 7 Home Basic SP1 or later
    Microsoft Windows 7 Home Premium SP1 or later
    Microsoft Windows 7 Professional SP1 or later
    Microsoft Windows 7 Enterprise SP1 or later
    Microsoft Windows 7 Ultimate SP1 or later

    This software should work but is not tested yet with the following 32 and 64 bit Microsoft operating systems. 

    Microsoft Windows 8
    Microsoft Windows 8 Pro
    Microsoft Windows 8 Enterprise
    Microsoft Windows 8.1
    Microsoft Windows 8.1 Pro
    Microsoft Windows 8.1 Enterprise

Where to find us?

Address
Hyttrisvägen 27, SE-770 14 Nyhammar. Sweden
Phone Number
+46-(0)240-64 11 10
Email: info@elcon.se
Order: order@elcon.se
We use cookies
We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you will not be able to create an account or use all the functionalities of the site.